Re: Required Landings, Article 9.8.4.2.
Project Description
The subject building is a house with an attached garage. Access from the dwelling unit to the garage is through a door with its swing into the garage. The door swings over a stair, which has two risers.
Sentence 9.8.4.2. (1) states where a door swings toward a stair, the full arc of its swing shall be over a landing. Sentence 9.8.4.2.(4) states a landing shall be provided at the top of all exterior stairs, except that a landing may be omitted at a secondary entrance to a building containing a single dwelling unit provided the stair does not contain more than 3 risers.
The appellant considers the door between the garage and the dwelling unit to be a secondary entrance to the building and that the exemption stated in Sentence 9.8.4.2.(4) is applicable.
The Building Official considers that Sentence 9.8.4.2.(1) is applicable. This requires the full arc of the door swing to be over a landing.
It is the determination of the Board that Sentence 9.8.4.2.(1) applies and a landing is required or the door must swing into the adjacent hallway. Sentence 9.8.4.2.(4) is not applicable because the door in question is not an exterior door.